ID: 9956

63A Automatic reconnect circuit breaker with over and under voltage over current Leakage protection surge protect relay

5.0 (3 votes) | 13 orders
Price:
US $ 54.40 / piece
Quantity

Rated voltage: AC220V 50Hz/60Hz

Power consumption: <3W

Supply voltage: AC140V~320V

When the voltage current is normal the product will Automatic reconnect.

Leakage range: 10~90mA(adjustable)(Default 30mA)  Leakage response time: ≤0.1S

Over voltage range: AC230~300V(adjustable)(Default 270V) Overvoltage response time: ≤0.1S

Low voltage range: AC145~210V(adjustable)(Default 170V) Low voltage response time: ≤0.1S

Over current range: 1~63A (adjustable)  (Default 40A) Overcurrent range response time: ≤0.1S

Short-circuit current: ≥31ln  Short-circuit response time: ≤0.1S

Lightning protection: Test the switch with a combination wave of 1.2/50us (8/20us) between the L-N wires. No failure is found under the voltage of 2KV and no damage under 6KV.

Error in real-time current, voltage and leakage current: ≤5%

  1. Purpose

It is intended for a circuit of AC 50Hz/60Hz with maximum rated current of 63A to protect it and the equipment involved against overvoltage, low voltage, current surge, leakage, lightning, etc.

It is applicable to such electrical equipment as communication base stations, repeaters, video surveillance, Safety City, cable TV, digital TV, network switches, optical transceivers, meteorological telemetry stations, seismic detection stations in various conditions.

  1. Features

Detection before closing: The automatic reclosing power protection switch monitors the circuit and will not close in occurrence of any overvoltage, leakage, overcurrent and other failures.

Overvoltage protection: When the voltage between the live wire and naught wire of the input terminal is greater than the set value, it will trip the switch for protection.

Low voltage protection: When the voltage between the live wire and naught wire of the input terminal is less than the set value, it will trip the switch for protection.

Overcurrent protection: When the actual current is greater than or equal to 1.15 times the rated current for 3 seconds, it will trip the switch for protection.

Leakage protection: When the leakage current exceeds the set value or an electric shock occurs, the automatic reclosing switch will be disconnected within 0.1 seconds to ensure personal safety.

Neutral line disconnection protection: When the three-phase voltage is unbalanced to a certain level due to the loose or cut-off external Neutral line, the switch is tripped for protection.

Automatic disconnection when power’s off: The switch will be automatically disconnected when the circuit is powered off, and will be automatically reclosed after detecting a normal power supply restored.

Intelligent leakage identification: Automatically detect before closing if the voltage is normal and the Neutral line is well-connected and never close in case of any failure.

Automatic reclosing: Automatically reclose after a certain time interval if the above failure occurs.

Automatically save tripping information: Automatically save such tripping information as tripping time, tripping type (cause), voltage, current and leakage current for failure analysis.

3.Main technical parameters

Rated voltage: AC220V 50Hz/60Hz

Power consumption: <3W

Supply voltage: AC140V~320V

Leakage range: 10~90mA  Leakage response time: ≤0.1S

Overvoltage range: AC220~300V  Overvoltage response time: ≤0.1S

Low voltage range: AC145~210V  Low voltage response time: ≤0.1S

Overcurrent range: 1~63A  Overcurrent range response time: ≤0.1S

Short-circuit current: ≥31ln  Short-circuit response time: ≤0.1S

Lightning protection: Test the switch with a combination wave of 1.2/50us (8/20us) between the L-N wires. No failure is found under the voltage of 2KV and no damage under 6KV.

Error in real-time current, voltage and leakage current: ≤5%

Max. failure records: 999

Working conditions:

Temperature: -20℃~55℃  Storage temperature: -45℃~80℃

Humidity: ≤95%Rh  Atmospheric pressure: 70kPa~106kPa

Volume: 106X92X70mm

 

  1. Operating procedures and panel instructions

4.1 Main panel operations

IMG_20180912_183435

  1. Press the set key: check the actual current, voltage and leakage current.
  2. Parameter setting
  • Long press the setting key for 5 seconds to enter the setting mode.
  • The voltage indicator lights on with the actual overvoltage value (270V by default) displayed. Press Up key to 300V to the maximum or Down key to 230V to the minimum (press Up key again to close the setting if not required).
  • Long press the setting key and the voltage indicator lights on with the actual low voltage value (170V by default) displayed. Press Up key to 210V to the maximum or Down key to 145V to the minimum. Press Down key again to close the setting if not required.
  • Press the setting key and the current indicator lights on (40A by default). Press Up key to 63A to the maximum or Down key to 1A to the minimum.
  • Press the setting key and the leakage current indicator lights on (30mA by default). Press Up key to 90mA to the maximum or Down key to 10mA to the minimum (press Up key again to close the setting if not required).

 

Connect the power supply after well wiring the automatic reclosing power protection switch. Turn on the “Master Switch” to enable the automatic reclosing switch to turn on the circuit. And then press the “Test” button to enable the switch to turn off the circuit. The leakage indicator is on and the power is restored automatically 10 seconds later, indicating the switch functions well and has been installed correctly. Now you can be assured by the safety and convenience that the switch brings you.

It is highly recommended to conduct above test regularly to make sure the switch functions well.

In case of no need of electricity, you can turn off the "Master Switch" to enable the automatic reclosing power protection switch to disconnect the circuit, which is equivalent to shut all the power off.

1. Turn on the power switch after power is on. The operating indicator lights on, indicating the automatic reclosing power protection switch is powered on.

2. The switch automatically closes with the output indicator on the panel on, indicating the power supply is normal.

3. The switch disconnects the circuit upon any electricity leakage of equipment, indicating the leakage function works well. The leakage indicator lights on and the switch will attempt the first reclosing after 30 seconds.

If the leakage persists, the switch will immediately open and attempt the second reclosing 5 minutes later. If the problem persists, attempt the third reclosing 10 minutes later. If it persists, attempt the fourth reclosing 30 minutes later. If it still does, then attempt the fifth reclosing 1 hour later. After 5 times of reclosing, the switch will restart to check the circuit after 3 hours and attempt 5 times of reclosing again if the leakage is still unsolved.

4. The reclosing attempts to leakage failure are the same as those to overvoltage, low voltage and overcurrent failures.

  1. Installation for use

(1)Install the automatic reclosing power protection switch on the wall or in the main unit case to avoid direct rain and sun exposure.

(2)Connect the product to the bottom of the circuit breaker (or the knife switch) with the power supply connected to the input terminal and the load to the output terminal.

(3)The red indicator lighting on after 10 seconds of powering up indicates that the circuit comes up against some kind of failure. Turn off the switch and on again after 10 seconds. If it persists, it may indicate that there has abnormal leakage current or overcurrent/short circuit. At this point all loads should be disconnected to find out the reasons and troubleshoot the problems before restoring power.

(4)Adjust the rated current after installation.

(5)Connect the product with the single-phase 230V power supply, the electrical equipment circuit and the grounding wire according to the marks on the panel. Please be noted that the input and output terminals cannot be wrongly connected.

 

  1. Wiring:you don't need to connect to GND, if you don't have GNDwire

Note 1: This switch cannot be used as a master breaker. Please install a miniature circuit breaker as an overload short-circuiting fitting in front of the switch.

Note 2: Please adjust the current after installation.

Note 3: This product is designed without isolation function. Please disconnect the front breaker before repairing the circuit.

IMG_20180912_182353IMG_20180912_182427IMG_20180912_182445

Shipping:

  • We Ship to Worldwide, except APO/FPO.

  • Items are shipped from China using Airmail, reach most of the countries within 10 to 20 business days.

  • Delivery time depends on destination and other factors, it may takes up to 20 business days

  • Noted: Fedex Maybe charge handling charges at your country, we are not responsible for this charges.

Payment:

       Payment method on Hogaki Check here http://help.Hogaki.com/payment_method.htm

Warranty and Guarantee:

  • 12 months Warranty. Buy with confidence!

  • If you are not satisfied when you receive your item, please return it within 14 days for a replacement or money back. Please contact me before you return it.

  • If item is defective in 3 months, We will send you a replacement without extra charger, or offer refund after we receive the defective item.

  • If item is defective after 3 months, you can still send it back to us. We will send you a new one after receiving the defective item. But you have to pay the extra shipping fee

Other Policies:

  • We are not responsible for any custom duty or import tax.

  • We will leave POSITIVE FEEDBACK after receiving the payment. Please contact us if you are not satisfied with the item after receive it.

  • All emails will be answered within 1 business day. If you do not receive our reply, please kindly re-sent your email and we will reply to you as soon as possible.

  • Serious Buyer Only! Please place bid only if you agree with all the terms


  • is_customized: Yes
  • Model Number: TOMPD-63
  • Type: Mini
  • Brand Name: TOMZN
  • Poles Number: 2
  • Rated current: 63A
  • Mounting: 35mm din rail
  • Rated Voltage: 230V 50/60Hz
  • Phase: Single phase
  • Over voltage protection: 230~300V(adjustable)(Default 270V)
  • Under voltage protection: 145~210V(adjustable)(Default 170V)
  • Over current range: 1~63A (adjustable) (Default 40A)
  • Leakage range: 10~90mA(adjustable)(Default 30mA)

SHIPPING AND DELIVERY

We are proud to offer international shipping services that currently operate in over 200 countries and islands world wide. Nothing means more to us than bringing our customers great value and service. We will continue to grow to meet the needs of all our customers, delivering a service beyond all expectation anywhere in the world.

How do you ship packages?

Packages from our warehouse in China will be shipped by ePacket or EMS depending on the weight and size of the product. Packages shipped from our US warehouse are shipped through USPS.

Do you ship worldwide?

Yes. We provide free shipping to over 200 countries around the world. However, there are some location we are unable to ship to. If you happen to be located in one of those countries we will contact you.

What about customs?

We are not responsible for any custom fees once the items have shipped. By purchasing our products, you consent that one or more packages may be shipped to you and may get custom fees when they arrive to your country.

How long does shipping take?

Shipping time varies by location. These are our estimates:

Location *Estimated Shipping Time
United States 10-30 Business days
Canada, Europe 10-30 Business days
Australia, New Zealand 10-30 Business days
Central & South America 15-30 Business days
*This doesn’t include our 2-5 day processing time.

Do you provide tracking information?

Yes, you will receive an email once your order ships that contains your tracking information.

My tracking says “no information available at the moment”.

For some shipping companies, it takes 2-5 business days for the tracking information to update on the system.

Will my items be sent in one package?

For logistical reasons, items in the same purchase will sometimes be sent in separate packages, even if you've specified combined shipping.

If you have any other questions, please contact us and we will do our best to help you out.

REFUNDS & RETURNS POLICY

Order cancellation

All orders can be cancelled until they are shipped. If your order has been paid and you need to make a change or cancel an order, you must contact us within 12 hours. Once the packaging and shipping process has started, it can no longer be cancelled.

Refunds

Your satisfaction is our #1 priority. Therefore, if you’d like a refund you can request one no matter the reason.

If you did not receive the product within the guaranteed time(45 days not including 2-5 day processing) you can request a refund or a reshipment.

If you received the wrong item you can request a refund or a reshipment.

If you do not want the product you’ve receive you may request a refund but you must return the item at your expense and the item must be unused.

  • Your order did not arrive due to factors within your control (i.e. providing the wrong shipping address)
  • Your order did not arrive due to exceptional circumstances outside the control of HOGAKI.COM - Home, Garden & Kitchen shop (i.e. not cleared by customs, delayed by a natural disaster).
  • Other exceptional circumstances outside the control of hogaki.com

*You can submit refund requests within 15 days after the guaranteed period for delivery (45 days) has expired. You can do it by sending a message on Contact Us page

If you are approved for a refund, then your refund will be processed, and a credit will automatically be applied to your credit card or original method of payment, within 14 days.

Exchanges

If for any reason you would like to exchange your product, perhaps for a different size in clothing. You must contact us first and we will guide you through the steps.

Please do not send your purchase back to us unless we authorise you to do so.

LARGE ORDER DEALS

Wholesale

Thank you for your interest doing business with us!

If you would like to get a discounted price for your large purchase orders, fill in the required blanks along with your email address, the product Item ID # and/or the link of the item that you want to order, item quantity (minimum of 30 pieces), shipping country and payment method is required. We will contact you with a discounted price as soon as we receive your inquiry.

You may also like these products